Rated current (In): 6A, 10A, 16A, 20A, 25A, 32A, 40A.
Rated voltage (Ue): 230V AC.
Breaking capacity (lcn): 6kA.
Rated residual current: 30mA, 100mA.
Tripping characteristic: B,C.
Electrical endurance: 4000 cycles.
Mechanical endurance: 100000 cycles
Standard:BS EN 61009-1.
Type: AC, A.
Brand:Laiwo
Email:sales@wosom.cn
Telephone:+86-15067706272
whatsapp:+86-15067706272
WAMR is a range of MCB sized RCBOs, apply to circuit of AC50/60Hz. Rated voltage to 230V, and current up to 40A, bring higher levels of safety to an electrical installation and its users because they include switched neutral as standard, which will guarantee that healthy circuits remain in service and that only a faulty circuit is switched off and bring cost savings by reducing installation and testing times.
Part No | Description | Box Qty |
WAMR106B-140B/030 | Single Module 6Amps-40Amps B Curve 30mA | 60 |
WAMR106B-140B/100 | Single Module 6Amps-40Amps B Curve 100mA | 60 |
WAMR106C-140B/030 | Single Module 6Amps-40Amps C Curve 30mA | 60 |
WAMR106C-140B/100 | Single Module 6Amps-40Amps C Curve 100mA | 60 |
The WAMR Leakage Protection Switch is designed to enhance electrical safety by detecting and preventing leakage currents in various applications, including residential, commercial, and industrial settings. This switch provides essential protection against electric shock and electrical fires by monitoring residual currents and quickly disconnecting the circuit in the event of a fault. Its compact design ensures easy installation in standard distribution boards, making it a convenient choice for upgrading electrical systems. The WAMR switch features a user-friendly test button for regular functionality checks, along with a clear indicator for operational status. Compliant with national electrical safety standards, it guarantees reliable performance and peace of mind. With its durable construction and efficient response time, the WAMR Leakage Protection Switch is an indispensable component for safeguarding both people and property from electrical hazards.
Switching and isolation.
Overload and short circuit protection.
Protection against the effects of sinusoidal alternation earth fault currents.
Indirect and direct contacts protection.
Protection against fire hazard caused by insulation faults.
Rated current (In): 6A, 10A, 16A, 20A, 25A, 32A, 40A.
Rated voltage (Ue): 230V AC.
Breaking capacity (lcn): 6kA.
Rated residual current: 30mA, 100mA.
2pole.
Tripping characteristic: B,C.
Electrical endurance: 4000 cycles.
Mechanical endurance: 100000 cycles
Complies with BS EN 61009-1.
Type: AC, A.
INQUIRY NOW